For troubleshooting common issues, please refer to the list below. We also have a variety of
Frequently Asked Questions (FAQ's) that offer more detailed support including:
Review our CoilJet Troubleshooting guide first
My CoilJet doesn't power on. What could be causing this?
My battery doesn't seem to be holding a charge. What could be the reason?
What is the best type of coil cleaner to use with the CoilJet?
CoilJet Warranty Information
See more
If you continue to have issue with you CoilJet, please
contact us.
Problem
|
Probable Cause |
Recommended Remedy |
Inconsistent and/or erratic pressure
|
Nozzle worn
Nozzle clogged
Water/chemical is low
Air sucked into system
Air in pump (not properly primed)
Vacuum lock (cap vent clogged)
Water temp too high
Low battery |
Replace nozzle
Clean nozzle orifice
Add water and/or chemical
Fill Tanks(s)
Remove nozzle, prime pump
Clean cap air vent
Add cold water to reduce temp
Charge or replace battery
|
Motor continues to run even though
trigger is released |
High pressure system or pump hydraulic circuit not watertight
Air in system
Tank(s) Empty |
Check for leaks at spray gun and pump
Re-prime the unit
Fill tank(s) |
Motor stops abruptly
|
Battery too low to operate
Battery wire(s) not connected
Power switch off
Thermal breaker tripped |
Charge or replace battery
Check battery wires
Turn switch on
Turn off, let unit cool |
Motor buzzes but fails to start or
does not start at all |
Problems with pump auto shut-off
Unit in disuse for extended time
Pressure needs to be relieved |
Contact factory
Contact factory
Squeeze trigger and relieve pressure |
If, after attempting these troubleshooting tips, you continue to have problems with your CoilJet, please
contact us.